Part Number Hot Search : 
L12PFI M37212 300195Z BF1211R B8279 BYG23T MBRB2 E3SGS3B4
Product Description
Full Text Search
 

To Download CS2200-OTP09 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 CS2200-OTP
Fractional-N Frequency Synthesizer
Features
Delta-Sigma Fractional-N Frequency Synthesis
General Description
The CS2200-OTP is an extremely versatile system clocking device that utilizes a programmable phase lock loop. The CS2200-OTP is based on an analog PLL architecture comprised of a Delta-Sigma Fractional-N Frequency Synthesizer. This architecture allows for frequency synthesis and clock generation from a stable reference clock. The CS2200-OTP has many configuration options which are set once prior to runtime. At runtime there are three hardware configuration pins available for mode and feature selection. The CS2200-OTP is available in a 10-pin MSOP package in Commercial (-10C to +70C) grade. Customer development kits are also available for custom device prototyping, small production programming, and device evaluation. Please see "Ordering Information" on page 23 for complete details.
-
Generates a Low Jitter 6 - 75 MHz Clock Relative to 8 - 75 MHz Reference Clock
Highly Accurate PLL Multiplication Factor
-
Maximum Error Less Than 1 PPM
One-Time Programmability
- -
Configurable Hardware Control Pins Configurable Auxiliary Output
Flexible Sourcing of Reference Clock
- -
External Oscillator or Clock Source Supports Inexpensive Local Crystal
Minimal Board Space Required
-
No External Analog Loop-filter Components
3.3 V
Timing Reference
Hardware Control
Hardware Configuration
PLL Output PLL Lock Indicator
Auxiliary Output
8 MHz to 75 MHz Low-Jitter Timing Reference
Phase Comparator
Internal Loop Filter
Voltage Controlled Oscillator
6 to 75 MHz PLL Output
Fractional-N Divider
Delta-Sigma Modulator
N
Output to Input Clock Ratio
http://www.cirrus.com
Copyright Cirrus Logic, Inc. 2009 (All Rights Reserved)
AUG '09 DS842F1
CS2200-OTP
TABLE OF CONTENTS
1. PIN DESCRIPTION ................................................................................................................................. 4 2. TYPICAL CONNECTION DIAGRAM ..................................................................................................... 5 3. CHARACTERISTICS AND SPECIFICATIONS ...................................................................................... 6 RECOMMENDED OPERATING CONDITIONS .................................................................................... 6 ABSOLUTE MAXIMUM RATINGS ........................................................................................................ 6 DC ELECTRICAL CHARACTERISTICS ................................................................................................ 6 AC ELECTRICAL CHARACTERISTICS ................................................................................................ 7 4. ARCHITECTURE OVERVIEW ............................................................................................................... 8 4.1 Delta-Sigma Fractional-N Frequency Synthesizer ........................................................................... 8 5. APPLICATIONS ..................................................................................................................................... 9 5.1 One Time Programmability .............................................................................................................. 9 5.2 Timing Reference Clock Input .......................................................................................................... 9 5.2.1 Internal Timing Reference Clock Divider ................................................................................. 9 5.2.2 Crystal Connections (XTI and XTO) ...................................................................................... 10 5.2.3 External Reference Clock (REF_CLK) .................................................................................. 10 5.3 Output to Input Frequency Ratio Configuration ............................................................................. 11 5.3.1 User Defined Ratio (RUD) ..................................................................................................... 11 5.3.2 Ratio Modifier (R-Mod) .......................................................................................................... 11 5.3.3 Effective Ratio (REFF) .......................................................................................................... 11 5.3.4 Ratio Configuration Summary ............................................................................................... 12 5.4 PLL Clock Output ........................................................................................................................... 13 5.5 Auxiliary Output .............................................................................................................................. 14 5.6 Mode Pin Functionality ................................................................................................................... 14 5.6.1 M1 and M0 Mode Pin Functionality ....................................................................................... 14 5.6.2 M2 Mode Pin Functionality .................................................................................................... 15 5.6.2.1 M2 Configured as Output Disable .............................................................................. 15 5.6.2.2 M2 Configured as R-Mod Enable .............................................................................. 15 5.6.2.3 M2 Configured as AuxOutSrc Override ..................................................................... 15 5.7 Clock Output Stability Considerations ............................................................................................ 16 5.7.1 Output Switching ................................................................................................................... 16 5.7.2 PLL Unlock Conditions .......................................................................................................... 16 5.8 Required Power Up Sequencing for Programmed Devices ........................................................... 16 6. PARAMETER DESCRIPTIONS ........................................................................................................... 17 6.1 Modal Configuration Sets ............................................................................................................... 17 6.1.1 R-Mod Selection (RModSel[1:0]) ........................................................................................... 17 6.1.2 Auxiliary Output Source Selection (AuxOutSrc[1:0]) ............................................................. 18 6.2 Ratio 0 - 3 ...................................................................................................................................... 18 6.3 Global Configuration Parameters ................................................................................................... 18 6.3.1 AUX PLL Lock Output Configuration (AuxLockCfg) .............................................................. 18 6.3.2 Reference Clock Input Divider (RefClkDiv[1:0]) .................................................................... 18 6.3.3 Enable PLL Clock Output on Unlock (ClkOutUnl) ................................................................. 19 6.3.4 M2 Pin Configuration (M2Config[2:0]) ................................................................................... 19 7. CALCULATING THE USER DEFINED RATIO .................................................................................... 20 7.1 12.20 Format .................................................................................................................................. 20 8. PROGRAMMING INFORMATION ........................................................................................................ 21 9. PACKAGE DIMENSIONS .................................................................................................................... 22 THERMAL CHARACTERISTICS ......................................................................................................... 22 10. ORDERING INFORMATION .............................................................................................................. 23 11. REVISION HISTORY .......................................................................................................................... 24
DS842F1
2
CS2200-OTP
LIST OF FIGURES
Figure 1. Typical Connection Diagram ........................................................................................................ 5 Figure 2. Delta-Sigma Fractional-N Frequency Synthesizer ....................................................................... 8 Figure 3. Internal Timing Reference Clock Divider ..................................................................................... 9 Figure 4. REF_CLK Frequency vs a Fixed CLK_OUT .............................................................................. 10 Figure 5. External Component Requirements for Crystal Circuit .............................................................. 10 Figure 6. Ratio Feature Summary ............................................................................................................. 12 Figure 7. PLL Clock Output Options ......................................................................................................... 13 Figure 8. Auxiliary Output Selection .......................................................................................................... 14 Figure 9. M2 Mapping Options .................................................................................................................. 15 Figure 10. Parameter Configuration Sets .................................................................................................. 17
LIST OF TABLES
Table 1. Modal and Global Configuration .................................................................................................... 9 Table 2. Ratio Modifier .............................................................................................................................. 11 Table 3. Example 12.20 R-Values ............................................................................................................ 20
DS842F1
3
CS2200-OTP 1. PIN DESCRIPTION
VD GND CLK_OUT AUX_OUT TST_IN
1 2 3 4 5
10 9 8 7 6
M0 M1 M2 XTI/REF_CLK XTO
Pin Name
VD GND CLK_OUT AUX_OUT TST_IN XTO XTI/REF_CLK M2 M1 M0
#
1 2 3 4 5
Pin Description
Digital Power (Input) - Positive power supply for the digital and analog sections. Ground (Input) - Ground reference. PLL Clock Output (Output) - PLL clock output. Auxiliary Output (Output) - This pin outputs a buffered version of one of the input or output clocks, or a status signal, depending on configuration. Test Input (Input) - This pin is for factory test purposes and must be connected to GND for proper operation. Crystal Connections (XTI/XTO) / Timing Reference Clock Input (REF_CLK) (Input/Output) XTI/XTO are I/O pins for an external crystal which may be used to generate the low-jitter PLL input clock. REF_CLK is an input for an externally generated low-jitter reference clock. Mode Select (Input) - M2 is a configurable mode selection pin. Mode Select (Input) - M1 is a configurable mode selection pin.
6 7 8 9
10 Mode Select (Input) - M0 is a configurable mode selection pin.
4
DS842F1
CS2200-OTP 2. TYPICAL CONNECTION DIAGRAM
0.1 F
1 F
+3.3 V
VD M2 System Microcontroller M1 M0
CS2200-OTP
CLK_OUT XTI/REF_CLK XTO To circuitry which requires a low-jitter clock To other circuitry or Microcontroller
1 or 2
AUX_OUT
GND
TST_IN
Low-Jitter Timing Reference
REF_CLK
1
N.C. x
XTO
or Crystal XTI
2
XTO
40 pF 40 pF
Figure 1. Typical Connection Diagram
DS842F1
5
CS2200-OTP 3. CHARACTERISTICS AND SPECIFICATIONS RECOMMENDED OPERATING CONDITIONS
GND = 0 V; all voltages with respect to ground. (Note 1) Parameters
DC Power Supply Ambient Operating Temperature (Power Applied) Commercial Grade TAC -10 +70 C
Symbol
VD
Min
3.1
Typ
3.3
Max
3.5
Units
V
Notes: 1. Device functionality is not guaranteed or implied outside of these limits. Operation outside of these limits may adversely affect device reliability.
ABSOLUTE MAXIMUM RATINGS
GND = 0 V; all voltages with respect to ground. Parameters
DC Power Supply Input Current Digital Input Voltage (Note 2) Ambient Operating Temperature (Power Applied) Storage Temperature
Symbol
VD IIN VIN TA Tstg
Min
-0.3 -0.3 -55 -65
Max
6.0 10 VD + 0.4 125 150
Units
V mA V C C
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Notes: 2. The maximum over/under voltage is limited by the input current except on the power supply pin.
DC ELECTRICAL CHARACTERISTICS
Test Conditions (unless otherwise specified): VD = 3.1 V to 3.5 V; TA = -10C to +70C (Commercial Grade). Parameters
Power Supply Current - Unloaded Power Dissipation - Unloaded Input Leakage Current Input Capacitance High-Level Input Voltage Low-Level Input Voltage High-Level Output Voltage (IOH = -1.2 mA) Low-Level Output Voltage (IOH = 1.2 mA) (Note 3) (Note 3)
Symbol
ID PD IIN IC VIH VIL VOH VOL
Min
70% 80% -
Typ
12 40 8 -
Max
18 60 10 30% 20%
Units
mA mW A pF VD VD VD VD
Notes: 3. To calculate the additional current consumption due to loading (per output pin), multiply clock output frequency by load capacitance and power supply voltage. For example, fCLK_OUT (49.152 MHz) * CL (15 pF) * VD (3.3 V) = 2.4 mA of additional current due to these loading conditions on CLK_OUT.
6
DS842F1
CS2200-OTP AC ELECTRICAL CHARACTERISTICS
Test Conditions (unless otherwise specified): VD = 3.1 V to 3.5 V; TA = -10C to +70C (Commercial Grade); CL = 15 pF. Parameters
Crystal Frequency Fundamental Mode XTAL Reference Clock Input Frequency
Symbol
fXTAL
Conditions RefClkDiv[1:0] = 10 RefClkDiv[1:0] = 01 RefClkDiv[1:0] = 00 RefClkDiv[1:0] = 10 RefClkDiv[1:0] = 01 RefClkDiv[1:0] = 00
Min
8 16 32 8 16 32 45 8 6
Typ
50 1.7 1.7 70 50 175 1 -
Max
14 28 50 14 28 56 55 14 75 55 3.0 3.0 3 0.5
Units
MHz MHz MHz MHz MHz MHz % MHz MHz % ns ns ps rms ps rms ps rms ms ppm
fREF_CLK
Reference Clock Input Duty Cycle Internal System Clock Frequency PLL Clock Output Frequency PLL Clock Output Duty Cycle Clock Output Rise Time Clock Output Fall Time Period Jitter Base Band Jitter (100 Hz to 40 kHz) Wide Band JItter (100 Hz Corner) PLL Lock Time - REF_CLK Output Frequency Synthesis Resolution (Note 7)
DREF_CLK fSYS_CLK fCLK_OUT tOD tOR tOF tJIT Measured at VD/2 20% to 80% of VD 80% to 20% of VD (Note 4) (Notes 4, 5) (Notes 4, 6) tLR ferr fREF_CLK = 8 to 75 MHz
45 0
Notes: 4. fCLK_OUT = 24.576 MHz; Sample size = 10,000 points; AuxOutSrc[1:0] = 11. 5. In accordance with AES-12id-2006 section 3.4.2. Measurements are Time Interval Error taken with 3rd order 100 Hz to 40 kHz bandpass filter. 6. In accordance with AES-12id-2006 section 3.4.1. Measurements are Time Interval Error taken with 3rd order 100 Hz Highpass filter. 7. The frequency accuracy of the PLL clock output is directly proportional to the frequency accuracy of the reference clock.
DS842F1
7
CS2200-OTP 4. ARCHITECTURE OVERVIEW
4.1 Delta-Sigma Fractional-N Frequency Synthesizer
The core of the CS2200 is a Delta-Sigma Fractional-N Frequency Synthesizer which has very high-resolution for Input/Output clock ratios, low phase noise, very wide range of output frequencies and the ability to quickly tune to a new frequency. In very simplistic terms, the Fractional-N Frequency Synthesizer multiplies the Timing Reference Clock by the value of N to generate the PLL output clock. The desired output to input clock ratio is the value of N that is applied to the delta-sigma modulator (see Figure 2). The analog PLL based frequency synthesizer uses a low-jitter timing reference clock as a time and phase reference for the internal voltage controlled oscillator (VCO). The phase comparator compares the fractional-N divided clock with the original timing reference and generates a control signal. The control signal is filtered by the internal loop filter to generate the VCO's control voltage which sets its output frequency. The delta-sigma modulator modulates the loop integer divide ratio to get the desired fractional ratio between the reference clock and the VCO output (thus the duty cycle of the modulator sets the fractional value). This allows the design to be optimized for very fast lock times for a wide range of output frequencies without the need for external filter components. As with any Fractional-N Frequency Synthesizer the timing reference clock should be stable and jitter-free.
Timing Reference Clock
Phase Comparator
Internal Loop Filter
Voltage Controlled Oscillator
PLL Output
Fractional-N Divider
Delta-Sigma Modulator
N
Figure 2. Delta-Sigma Fractional-N Frequency Synthesizer
8
DS842F1
CS2200-OTP 5. APPLICATIONS
5.1 One Time Programmability
The one time programmable (OTP) circuitry in the CS2200-OTP allows for pre-configuration of the device prior to use in a system. There are two types of parameters that are used for device pre-configuration: modal and global. The modal parameters are features which, when grouped together, create a modal configuration set (see Figure 10 on page 17). Up to four modal configuration sets can be permanently stored and then dynamically selected using the M[1:0] mode select pins (see Table 1). The global parameters are the remaining configuration settings which do not change with the mode select pins. The modal and global parameters can be pre-set at the factory or user programmed using the customer development kit, CDK2000; Please see "Programming Information" on page 21 for more details. Parameter Type
Modal Global
M[1:0] pins = 00
Configuration Set 0 Ratio 0
M[1:0] pins = 01
Configuration Set 1 Ratio 1
M[1:0] pins = 10
Configuration Set 2 Ratio 2
M[1:0] pins = 11
Configuration Set 3 Ratio 3
Configuration settings set once for all modes.
Table 1. Modal and Global Configuration
5.2
Timing Reference Clock Input
The low jitter timing reference clock (RefClk) can be provided by either an external reference clock or an external crystal in conjunction with the internal oscillator. In order to maintain a stable and low-jitter PLL output the timing reference clock must also be stable and low-jitter; the quality of the timing reference clock directly affects the performance of the PLL and hence the quality of the PLL output.
5.2.1
Internal Timing Reference Clock Divider
The Internal Timing Reference Clock (SysClk) is limited to a lower maximum frequency than that allowed on the XTI/REF_CLK pin. The CS2200-OTP supports the wider external frequency range by offering an internal divider for RefClk. The RefClkDiv[1:0] global parameter should be configured such that SysClk, the divided RefClk, then falls within the valid range as indicated in "AC Electrical Characteristics" on page 7.
Timing Reference Clock Divider
Internal Timing Reference Clock 8 MHz < SysClk < 14 MHz
Timing Reference Clock XTI/REF_CLK 8 MHz < RefClk <
50 MHz (XTI) 58 MHz (REF_CLK)
/1 /2 /4
Fractional-N Frequency Synthesizer
PLL Output
RefClkDiv[1:0]
N
Figure 3. Internal Timing Reference Clock Divider It should be noted that the maximum allowable input frequency of the XTI/REF_CLK pin is dependent upon its configuration as either a crystal connection or external clock input. See the "AC Electrical Characteristics" on page 7 for more details. For the lowest possible output jitter, attention should be paid to the absolute frequency of the Timing Reference Clock relative to the PLL Output frequency (CLK_OUT). To minimize output jitter, the Timing Reference Clock frequency should be chosen such that fRefClk is at least +/-15 kHz from fCLK_OUT*N/32 where N is an integer. Figure 4 shows the effect of varying the RefClk frequency around fCLK_OUT*N/32. It should be noted that there will be a jitter null at the zero point when N = 32 (not shown in Figure 4). An DS842F1 9
CS2200-OTP
example of how to determine the range of RefClk frequencies around 12 MHz to be used in order to achieve the lowest jitter PLL output at a frequency of 12.288 MHz is as follows:
f L f RefClk f H where:
180 CLK__OUT Jitter
Typical Base Band Jitter (psec)
f L = f CLK_OUT x 31 + 15kHz ----32 = 12.288MHz x 0.96875 + 15kHz = 11.919MHz
*32/N f CLK__OUT 160
140
120
100 -15 kHz +15 kHz
and
f H = f CLK_OUT x 32 - 15kHz ----32 = 12.288MHz x 1 + 15kHz = 12.273MHz
80
60
40
20 -80 -60 -40 -20 0 20 40 60 80
Normalized REF__CLK Frequency (kHz)
Figure 4. REF_CLK Frequency vs a Fixed CLK_OUT
Referenced Control Parameter Definition
RefClkDiv[1:0] ......................."Reference Clock Input Divider (RefClkDiv[1:0])" on page 18
5.2.2
Crystal Connections (XTI and XTO)
An external crystal may be used to generate RefClk. To accomplish this, a 20 pF fundamental mode parallel resonant crystal must be connected between the XTI and XTO pins as shown in Figure 5. As shown, nothing other than the crystal and its load capacitors should be connected to XTI and XTO. Please refer to the "AC Electrical Characteristics" on page 7 for the allowed crystal frequency range.
XTI
XTO
40 pF
40 pF
Figure 5. External Component Requirements for Crystal Circuit
5.2.3
External Reference Clock (REF_CLK)
For operation with an externally generated REF_CLK signal, XTI/REF_CLK should be connected to the reference clock source and XTO should be left unconnected or terminated through a 47 k resistor to GND.
10
DS842F1
CS2200-OTP
5.3 5.3.1 Output to Input Frequency Ratio Configuration User Defined Ratio (RUD)
The User Defined Ratio, RUD, is a 32-bit un-signed fixed-point number which determines the basis for the desired input to output clock ratio. Up to four different ratios, Ratio0-3, can be stored in the CS2200's one time programmable memory. Selection between the four ratios is achieved by the M[1:0] mode select pins. The 32-bit RUD is represented in a 12.20 format where the 12 MSBs represent the integer binary portion while the remaining 20 LSBs represent the fractional binary portion. The maximum multiplication factor is approximately 4096 with a resolution of 0.954 PPM in this configuration. See "Calculating the User Defined Ratio" on page 20 for more information. The status of internal dividers, such as the internal timing reference clock divider, are automatically taken into account. Therefore RUD is simply the desired ratio of the output to input clock frequencies.
Referenced Control Parameter Definition Ratio 0-3................................"Ratio 0 - 3" on page 18 M[1:0] ...................................."M1 and M0 Mode Pin Functionality" on page 14
5.3.2
Ratio Modifier (R-Mod)
The Ratio Modifier is used to internally multiply/divide the currently addressed RUD (Ratio0-3 stored in the register space remain unchanged). The available options for R-Mod are summarized in Table 2 on page 11. R-Mod is enabled via the M2 pin in conjunction with the appropriate setting of the M2Config[2:0] global parameter (see Section 5.6.2 on page 15). RModSel[1:0] 00 01 10 11 R Modifier 0.5 0.25 0.125 0.0625 Table 2. Ratio Modifier
Referenced Control Parameter Definition Ratio 0-3................................"Ratio 0 - 3" on page 18 RModSel[1:0] ........................"R-Mod Selection (RModSel[1:0])" section on page 17 M2Config[2:0]........................"M2 Pin Configuration (M2Config[2:0])" on page 19
5.3.3
Effective Ratio (REFF)
The Effective Ratio (REFF) is an internal calculation comprised of RUD and the appropriate modifiers, as previously described. REFF is calculated as follows: REFF = RUD * R-Mod To simplify operation the device handles some of the ratio calculation functions automatically (such as when the internal timing reference clock divider is set). For this reason, the Effective Ratio does not need to be altered to account for internal dividers. Ratio modifiers which would produce an overflow or truncation of REFF should not be used. In all cases, the maximum and minimum allowable values for REFF are dictated by the frequency limits for both the input and output clocks as shown in the "AC Electrical Characteristics" on page 7.
DS842F1
11
CS2200-OTP
Selection of the user defined ratio from the four stored ratios is made by using the M[1:0] pins.
Referenced Control Parameter Definition M[1:0] pins............................."M1 and M0 Mode Pin Functionality" on page 14
5.3.4
Ratio Configuration Summary
The RUD is the user defined ratio for which up to four different values (Ratio0-3) can be stored in the one time programmable memory. The M[1:0] pins then select the user defined ratio to be used as well as the modal configuration set. R-Mod is applied accordingly. The user defined ratio and ratio modifier make up the effective ratio REFF, the final calculation used to determine the output to input clock ratio. The effective ratio is then corrected for the internal dividers. The conceptual diagram in Figure 6 summarizes the features involved in the calculation of the ratio values used to generate the fractional-N value which controls the Frequency Synthesizer. The subscript `4' indicates the modal parameters.
Timing Reference Clock (XTI/REF_CLK) Divide Effective Ratio REFF M[1:0] pins M2 pin SysClk RModSel[1:0]4 Ratio Format 12.20 Ratio 2 Ratio 3 Ratio Modifier RefClkDiv[1:0] Static Ratio, `N' RefClkDiv[1:0]
User Defined Ratio RUD Ratio 0 Ratio 1
Frequency Synthesizer
PLL Output
R Correction
Figure 6. Ratio Feature Summary
Referenced Control Parameter Definition Ratio 0-3................................"Ratio 0 - 3" on page 18 M[1:0] pins............................."M1 and M0 Mode Pin Functionality" on page 14 RModSel[1:0] ........................"R-Mod Selection (RModSel[1:0])" section on page 17 RefClkDiv[1:0] ......................."Reference Clock Input Divider (RefClkDiv[1:0])" on page 18
12
DS842F1
CS2200-OTP
5.4 PLL Clock Output
The PLL clock output pin (CLK_OUT) provides a buffered version of the output of the frequency synthesizer. The driver can be set to high-impedance with the M2 pin when the M2Config[1:0] global parameter is set to either 000 or 010. The output from the PLL automatically drives a static low condition while the PLL is unlocked (when the clock may be unreliable). This feature can be disabled by setting the ClkOutUnl global parameter, however the state CLK_OUT may then be unreliable during an unlock condition.
ClkOutUnl PLL Locked/Unlocked 0
0
2:1 Mux
1
M2 pin with M2Config[1:0] = 000, 010 0 PLL Clock Output PLLClkOut
2:1 Mux
PLL Output 1
PLL Clock Output Pin (CLK_OUT)
Figure 7. PLL Clock Output Options
Referenced Control Parameter Definition ClkOutUnl.............................."Enable PLL Clock Output on Unlock (ClkOutUnl)" on page 19 ClkOutDis .............................."M2 Configured as Output Disable" on page 15 M2Config[2:0]........................"M2 Pin Configuration (M2Config[2:0])" on page 19
DS842F1
13
CS2200-OTP
5.5 Auxiliary Output
The auxiliary output pin (AUX_OUT) can be mapped, as shown in Figure 8, to one of three signals: reference clock (RefClk), additional PLL clock output (CLK_OUT), or a PLL lock indicator (Lock). The mux is controlled via the AuxOutSrc[1:0] modal parameter. If AUX_OUT is set to Lock, the AuxLockCfg global parameter is then used to control the output driver type and polarity of the LOCK signal (see section 6.3.1 on page 18). If AUX_OUT is set to CLK_OUT, the phase of the PLL Clock Output signal on AUX_OUT may differ from the CLK_OUT pin. The driver for the pin can be set to high-impedance using the M2 pin when the M2Config[1:0] global parameter is set to either 001 or 010.
AuxOutSrc[1:0]
Timing Reference Clock (RefClk)
AuxOutDis
PLL Clock Output (PLLClkOut)
3:1 Mux
Auxiliary Output Pin (AUX_OUT)
PLL Lock/Unlock Indication (Lock)
AuxLockCfg
Figure 8. Auxiliary Output Selection
Referenced Control Parameter Definition AuxOutSrc[1:0]......................"Auxiliary Output Source Selection (AuxOutSrc[1:0])" on page 18 AuxOutDis ............................."M2 Configured as Output Disable" on page 15 AuxLockCfg..........................."AUX PLL Lock Output Configuration (AuxLockCfg)" section on page 18 M2Config[2:0]........................"M2 Pin Configuration (M2Config[2:0])" on page 19
5.6 5.6.1
Mode Pin Functionality M1 and M0 Mode Pin Functionality
M[1:0] determine the functional mode of the device and select both the default User Defined Ratio and the set of modal parameters. The modal parameters are RModSel[1:0] and AuxOutSrc[1:0]. By modifying one or more of the modal parameters between the 4 sets, different functional configurations can be achieved. However, global parameters are fixed and the same value will be applied to each functional configuration. Figure 10 on page 17 provides a summary of all parameters used by the device.
14
DS842F1
CS2200-OTP
5.6.2 M2 Mode Pin Functionality
M2 usage is mapped to one of the optional special functions via the M2Config[2:0] global parameter. Depending on what M2 is mapped to, it will either act as an output enable/disable pin or override certain modal parameters. Figure 9 summarizes the available options and the following sections will describe each option in more detail.
M2Config[2:0] global parameter
000 001 010 011 M2 pin 100 101 110 111
Disable CLK_OUT pin Disable AUX_OUT pin Disable CLK_OUT and AUX_OUT pins RModSel[1:0] Modal Parameter Enable Reserved Reserved Reserved Force AuxOutSel[1:0] = 10 (PLL Clock Out)
Figure 9. M2 Mapping Options
5.6.2.1
M2 Configured as Output Disable
If M2Config[2:0] is set to either `000', `001', or `010', M2 becomes an output disable pin for one or both output pins. If M2 is driven `low', the corresponding output(s) will be enabled, if M2 is driven `high', the corresponding output(s) will be disabled.
5.6.2.2
M2 Configured as R-Mod Enable
If M2Config[2:0] is set to `011', M2 becomes the R-Mod enable pin. It should be noted that M2 is the only way to enable R-Mod. Even though the RModSel[1:0] modal parameter can be set arbitrarily for each configuration set, it will not take effect unless enabled via M2. If M2 is driven `low', R-Mod will be disabled, if M2 is driven `high' R-Mod will be enabled.
5.6.2.3
M2 Configured as AuxOutSrc Override
If M2Config[2:0] is set to `111', M2 when driven `high' will override the AuxOutSrc[1:0] modal parameter and force the AUX_OUT source to PLL Clock Output. When M2 is driven `low', AUX_OUT will function according to AuxOutSrc[1:0].
DS842F1
15
CS2200-OTP
5.7 5.7.1 Clock Output Stability Considerations Output Switching
The CS2200-OTP is designed such that re-configuration of the clock routing functions do not result in a partial clock period on any of the active outputs (CLK_OUT and/or AUX_OUT). In particular, enabling or disabling an output, changing the auxiliary output source between REF_CLK and CLK_OUT, and the automatic disabling of the output(s) during unlock will not cause a runt or partial clock period. The following exceptions/limitations exist: * * Enabling/disabling AUX_OUT when AuxOutSrc[1:0] = 11 (unlock indicator). Switching AuxOutSrc[1:0] to or from 11 (unlock indicator) (Transitions between AuxOutSrc[1:0] = [00,10] will not produce a glitch).
When any of these exceptions occur, a partial clock period on the output may result.
5.7.2
PLL Unlock Conditions
Certain changes to the clock inputs and mode pins can cause the PLL to lose lock which will affect the presence of a clock signal on CLK_OUT. The following outlines which conditions cause the PLL to go unlocked: * * * Any change in the state of the M1 and M0 pins will cause the PLL to temporarily lose lock as the new setting takes affect. Changes made to the state of the M2 when the M2Config[2:0] global parameter is set to 011, 100, 101, or 110 can cause the PLL to temporarily lose lock as the new setting takes affect. Any discontinuities on the Timing Reference Clock, REF_CLK.
5.8
Required Power Up Sequencing for Programmed Devices
* * * Apply power. All input pins, except XTI/REF_CLK, should be held in a static logic hi or lo state until the `DC Power Supply' specification in the "Recommended Operating Conditions" table on page 6 are met. Apply input clock. For CDK programmed devices, toggle the state of the M0, M1, or both pins at least 3 times to initialize the device. This must be done after the power supply is stable and before normal operation is expected. Note: This operation is not required for factory programmed devices. After the specified PLL lock time on page 7 has passed, the device will output the desired clock as configured by the M0-M2 pins.
*
16
DS842F1
CS2200-OTP 6. PARAMETER DESCRIPTIONS
As mentioned in Section 5.1 on page 9, there are two different kinds of parameter configuration sets, Modal and Global. These configuration sets, shown in Figure 10, can be programmed in the field using the CDK2000 or preprogrammed at the factory. Please see "Programming Information" on page 21 for more details.
M[1:0] pins
Modal Configuration Set #0 Ratio 0 RModSel[1:0] AuxOutSrc[1:0]
00
Modal Configuration Set #1
Modal Configuration Set #2 Ratio 2 RModSel[1:0] AuxOutSrc[1:0]
10
Modal Configuration Set #3 Ratio 3 RModSel[1:0] AuxOutSrc[1:0]
11
Global Configuration Set AuxLockCfg RefClkDiv[1:0] ClkOutUnl M2Config[2:0]
Figure 10. Parameter Configuration Sets
6.1
Modal Configuration Sets
There are four instances of each of these configuration parameters. Selection between the four stored sets is made using the M[1:0] pins.
6.1.1
R-Mod Selection (RModSel[1:0])
Selects the R-Mod value, which is used as a factor in determining the PLL's Fractional N.
RModSel[1:0] 00 01 10 11 Application: R-Mod Selection Right-shift R-value by 1 (/ 2). Right-shift R-value by 2 (/ 4). Right-shift R-value by 3 (/ 8). Right-shift R-value by 4 (/ 16). "Ratio Modifier (R-Mod)" on page 11
Note: This parameter does not take affect unless M2 pin is high and the M2Config[2:0] global parameter is set to `011'.
DS842F1
Digital/PLL Core
17
Ratio 1
RModSel[1:0]
AuxOutSrc[1:0]
01
CS2200-OTP
6.1.2 Auxiliary Output Source Selection (AuxOutSrc[1:0])
Selects the source of the AUX_OUT signal.
AuxOutSrc[1:0] 00 01 10 11 Application: Auxiliary Output Source RefClk. Reserved. CLK_OUT. PLL Lock Status Indicator. "Auxiliary Output" on page 14
Note: When set to 11, the AuxLockCfg global parameter sets the polarity and driver type ("AUX PLL Lock Output Configuration (AuxLockCfg)" on page 18).
6.2
Ratio 0 - 3
The four 32-bit User Defined Ratios are stored in the CS2200's one time programmable memory. See "Output to Input Frequency Ratio Configuration" on page 11 and "Calculating the User Defined Ratio" on page 20 for more details.
6.3 6.3.1
Global Configuration Parameters AUX PLL Lock Output Configuration (AuxLockCfg)
When the AUX_OUT pin is configured as a lock indicator (AuxOutSrc[1:0] modal parameter = `11'), this global parameter configures the AUX_OUT driver to either push-pull or open drain. It also determines the polarity of the lock signal. If AUX_OUT is configured as a clock output, the state of this parameter is disregarded.
AuxLockCfg 0 1 Application: AUX_OUT Driver Configuration Push-Pull, Active High (output `high' for unlocked condition, `low' for locked condition). Open Drain, Active Low (output `low' for unlocked condition, high-Z for locked condition). "Auxiliary Output" on page 14
Note: AUX_OUT is an unlock indicator, signalling an error condition when the PLL is unlocked. Therefore, the pin polarity is defined relative to the unlock condition.
6.3.2
Reference Clock Input Divider (RefClkDiv[1:0])
Selects the input divider for the timing reference clock.
RefClkDiv[1:0] 00 01 10 11 Application: Reference Clock Input Divider / 4. / 2. / 1. Reserved. "Internal Timing Reference Clock Divider" on page 9 REF_CLK Frequency Range 32 MHz to 56 MHz (50 MHz with XTI) 16 MHz to 28 MHz 8 MHz to 14 MHz
18
DS842F1
CS2200-OTP
6.3.3 Enable PLL Clock Output on Unlock (ClkOutUnl)
Defines the state of the PLL output during the PLL unlock condition.
ClkOutUnl 0 1 Application: Clock Output Enable Status Clock outputs are driven `low' when PLL is unlocked. Clock outputs are always enabled (results in unpredictable output when PLL is unlocked). "PLL Clock Output" on page 13
6.3.4
M2 Pin Configuration (M2Config[2:0])
Controls which special function is mapped to the M2 pin.
M2Config[2:0] 000 001 010 011 100 101 110 111 Application: M2 pin function Disable CLK_OUT pin. Disable AUX_OUT pin. Disable CLK_OUT and AUX_OUT. RModSel[1:0] Modal Parameter Enable. Reserved. Reserved. Reserved. Force AuxOutSrc[1:0] = 10 (PLL Clock Out). "M2 Mode Pin Functionality" on page 15
DS842F1
19
CS2200-OTP 7. CALCULATING THE USER DEFINED RATIO
Note: The software for use with the evaluation kit has built in tools to aid in calculating and converting the User Defined Ratio. This section is for those who would like to know more about how the User Defined Ratio is calculated and stored.
Most calculators do not interpret the fixed point binary representation which the CS2200-OTP uses to define the output to input clock ratio (see Section 5.3.1 on page 11); However, with a simple conversion we can use these tools to generate a binary or hex value for Ratio0-3 to be stored in one time programmable memory. Please see "Programming Information" on page 21 for more details on programming.
7.1
12.20 Format
To calculate the User Defined Ratio (RUD) to store in the register(s), divide the desired output clock frequency by the given input clock (RefClk). Then multiply the desired ratio by the scaling factor of 220 to get the scaled decimal representation; then use the decimal to binary/hex conversion function on a calculator and write to the register. A few examples have been provided in Table 3. Desired Output to Input Clock Ratio (output clock/input clock)
12.288 MHz/10 MHz=1.2288 11.2896 MHz/44.1 kHz=256
Scaled Decimal Representation = (output clock/input clock) * 220 1288490 268435456
Hex Representation of Binary RUD 00 13 A9 2A 10 00 00 00
Table 3. Example 12.20 R-Values
20
DS842F1
CS2200-OTP 8. PROGRAMMING INFORMATION
Field programming of the CS2200-OTP is achieved using the hardware and software tools included with the CDK2000. The software tools can be downloaded from www.cirrus.com for evaluation prior to ordering a CDK. The CDK2000 is designed with built-in features to ease the process of programming small quantities of devices for prototype and small production builds. In addition to its field programming capabilities, the CDK2000 can also be used for the complete evaluation of programmed CS2200-OTP devices. The CS2200-OTP can also be factory programmed for large quantity orders. When ordering factory programmed devices, the CDK should first be used to program and evaluate the desired configuration. When evaluation is complete, the CS2000 Configuration Wizard is used to generate a file containing all device configuration information; this file is conveyed to Cirrus Logic as a complete specification for the factory programming configuration. Please contact your local Cirrus Logic sales representative for more information regarding factory programmed parts. See the CDK2000 datasheet, available at www.cirrus.com, for detailed information on the use of the CDK2000 programming and evaluation tools. Below is a form which represents the information required for programming a device (noted in gray). The "Parameter Descriptions" section beginning on page 17 describes the functions of each parameter. This form may be used either for personal notation for device configuration or it can be filled out and given to a Cirrus representative in conjunction with the programming file from the CDK2000 as an additional check. The User Defined Ratio may be filled out in decimal or it may be entered as hex as outlined in "Calculating the User Defined Ratio" on page 20. For all other parameters mark a `0' or `1' below the parameter name.
OTP Modal and Global Configuration Parameters Form Modal Configuration Set #0 Ratio 0 (dec) Ratio 0 (hex) __ __ : __ __ : __ __ : __ __ RModSel1 RModSel0 AuxOutSrc1 AuxOutSrc0
Modal Configuration Set #1 Ratio 1 (dec) Ratio 1 (hex) __ __ : __ __ : __ __ : __ __ RModSel1 RModSel0 AuxOutSrc1 AuxOutSrc0 Modal Configuration Set #2 Ratio 2 (dec) Ratio 2 (hex) __ __ : __ __ : __ __ : __ __ RModSel1 RModSel0 AuxOutSrc1 AuxOutSrc0 Modal Configuration Set #3 Ratio 3 (dec) Ratio 3 (hex) __ __ : __ __ : __ __ : __ __ RModSel1 RModSel0 AuxOutSrc1 AuxOutSrc0 Global Configuration Set AuxLockCfg RefClkDiv1
RefClkDiv0
ClkOutUnl
M2Cfg2
M2Cfg1
M2Cfg0
DS842F1
21
CS2200-OTP 9. PACKAGE DIMENSIONS 10L MSOP (3 mm BODY) PACKAGE DRAWING (Note 1)
N
D c E A2 A1
L
E11 A
e b END VIEW SIDE VIEW SEATING PLANE
L1
123
TOP VIEW
DIM
A A1 A2 b c D E E1 e L L1
MIN
-0 0.0295 0.0059 0.0031 ----0.0157 --
INCHES NOM
-----0.1181 BSC 0.1929 BSC 0.1181 BSC 0.0197 BSC 0.0236 0.0374 REF
MAX
0.0433 0.0059 0.0374 0.0118 0.0091 ----0.0315 --
MIN
-0 0.75 0.15 0.08 ----0.40 --
MILLIMETERS NOM
-----3.00 BSC 4.90 BSC 3.00 BSC 0.50 BSC 0.60 0.95 REF
NOTE MAX
1.10 0.15 0.95 0.30 0.23 ----0.80 --
4, 5 2 3
Notes: 1. Reference document: JEDEC MO-187 2. D does not include mold flash or protrusions which is 0.15 mm max. per side. 3. E1 does not include inter-lead flash or protrusions which is 0.15 mm max per side. 4. Dimension b does not include a total allowable dambar protrusion of 0.08 mm max. 5. Exceptions to JEDEC dimension.
THERMAL CHARACTERISTICS
Parameter
Junction to Ambient Thermal Impedance JEDEC 2-Layer JEDEC 4-Layer
Symbol
JA JA
Min
-
Typ
170 100
Max
-
Units
C/W C/W
22
DS842F1
CS2200-OTP 10.ORDERING INFORMATION
The CS2200-OTP is ordered as an un-programmed device. The CS2200-OTP can also be factory programmed for large quantity orders. Please see "Programming Information" on page 21 for more details.
Product
CS2200-OTP CS2200-OTP CDK2000
Description
Clocking Device Clocking Device Evaluation Platform
Package
10L-MSOP 10L-MSOP -
Pb-Free
Grade
Temp Range Container
-10 to +70C Rail Tape and Reel -
Order#
Yes Yes Yes Commercial -
CS2200P-CZZ CS2200P-CZZR CDK2000-CLK
-10 to +70C -
DS842F1
23
CS2200-OTP 11.REVISION HISTORY
Release
F1
Changes
Updated Period Jitter specification in "AC Electrical Characteristics" on page 7. Updated Crystal and Ref Clock Frequency specifications in "AC Electrical Characteristics" on page 7. Added Mode pin toggle requirement to startup for CDK programmed devices to "Required Power Up Sequencing for Programmed Devices" on page 16.
Contacting Cirrus Logic Support
For all product questions and inquiries, contact a Cirrus Logic Sales Representative. To find one nearest you, go to www.cirrus.com.
IMPORTANT NOTICE Cirrus Logic, Inc. and its subsidiaries ("Cirrus") believe that the information contained in this document is accurate and reliable. However, the information is subject to change without notice and is provided "AS IS" without warranty of any kind (express or implied). Customers are advised to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgment, including those pertaining to warranty, indemnification, and limitation of liability. No responsibility is assumed by Cirrus for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infringement of patents or other rights of third parties. This document is the property of Cirrus and by furnishing this information, Cirrus grants no license, express or implied under any patents, mask work rights, copyrights, trademarks, trade secrets or other intellectual property rights. Cirrus owns the copyrights associated with the information contained herein and gives consent for copies to be made of the information only for use within your organization with respect to Cirrus integrated circuits or other products of Cirrus. This consent does not extend to other copying such as copying for general distribution, advertising or promotional purposes, or for creating any work for resale. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL APPLICATIONS"). CIRRUS PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR USE IN PRODUCTS SURGICALLY IMPLANTED INTO THE BODY, AUTOMOTIVE SAFETY OR SECURITY DEVICES, LIFE SUPPORT PRODUCTS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF CIRRUS PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER'S RISK AND CIRRUS DISCLAIMS AND MAKES NO WARRANTY, EXPRESS, STATUTORY OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, WITH REGARD TO ANY CIRRUS PRODUCT THAT IS USED IN SUCH A MANNER. IF THE CUSTOMER OR CUSTOMER'S CUSTOMER USES OR PERMITS THE USE OF CIRRUS PRODUCTS IN CRITICAL APPLICATIONS, CUSTOMER AGREES, BY SUCH USE, TO FULLY INDEMNIFY CIRRUS, ITS OFFICERS, DIRECTORS, EMPLOYEES, DISTRIBUTORS AND OTHER AGENTS FROM ANY AND ALL LIABILITY, INCLUDING ATTORNEYS' FEES AND COSTS, THAT MAY RESULT FROM OR ARISE IN CONNECTION WITH THESE USES. Cirrus Logic, Cirrus, and the Cirrus Logic logo designs are trademarks of Cirrus Logic, Inc. All other brand and product names in this document may be trademarks or service marks of their respective owners.
24
DS842F1


▲Up To Search▲   

 
Price & Availability of CS2200-OTP09

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X